Biopotential monitoring

Biopotentials measurements are essential for biological research and biomedical monitoring of excitable tissues. This chapter provides an overview of biopotential monitoring, from the biological basis to the circuit and system techniques. Signal acquisition, processing, and transmission are fundamen...

Disgrifiad llawn

Wedi'i Gadw mewn:
Manylion Llyfryddiaeth
Prif Awdur: Oreggioni, Julián (author)
Awduron Eraill: Caputi, Ángel (author), Silveira, Fernando (author)
Fformat: article
Iaith:Saesneg
Cyhoeddwyd: 2019
Pynciau:
Mynediad Ar-lein:https://hdl.handle.net/20.500.12008/23468
Tagiau: Ychwanegu Tag
Dim Tagiau, Byddwch y cyntaf i dagio'r cofnod hwn!
_version_ 1868890224469213184
author Oreggioni, Julián
author2 Caputi, Ángel
Silveira, Fernando
author2_role author
author
author_browse Caputi, Ángel
Oreggioni, Julián
Silveira, Fernando
author_facet Oreggioni, Julián
Caputi, Ángel
Silveira, Fernando
author_role author
collection COLIBRI
dc.contributor.none.fl_str_mv Oreggioni Julián, Universidad de la República (Uruguay). Facultad de Ingeniería.
Caputi Ángel, Uruguay. Ministerio de Educación y Cultura. Instituto de Investigaciones Biológicas Clemente Estable.
Silveira Fernando, Universidad de la República (Uruguay). Facultad de Ingeniería.
dc.creator.none.fl_str_mv Oreggioni, Julián
Caputi, Ángel
Silveira, Fernando
dc.date.none.fl_str_mv 2019
2020-04-02T20:31:45Z
2020-04-02T20:31:45Z
dc.format.none.fl_str_mv 15 p.
application/pdf
dc.identifier.none.fl_str_mv Oreggioni, J, Caputi, Á y Silveira, F. Biopotential monitoring [en línea]. En: Encyclopedia of Biomedical Engineering. Amsterdam : Elsevier, 2019, pp. 296-304. ISBN: 978-0-12-805144-3.
978-0-12-805144-3
https://hdl.handle.net/20.500.12008/23468
dc.language.none.fl_str_mv en
eng
dc.publisher.none.fl_str_mv Elsevier
dc.relation.none.fl_str_mv Encyclopedia of Biomedical Engineering
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
dc.source.none.fl_str_mv reponame:COLIBRI
instname:Universidad de la República
instacron:Universidad de la República
dc.subject.none.fl_str_mv Analog front-end
Biomedical integrated circuit
Biopotential amplifier
Biopotential monitoring specifications
Biopotential organization levels
Biopotential sources
Low-power wireless communication
Neural recording
Wireless biopotential monitoring
INGENIERIA BIOMEDICA
dc.title.none.fl_str_mv Biopotential monitoring
dc.type.none.fl_str_mv Artículo
info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
description Biopotentials measurements are essential for biological research and biomedical monitoring of excitable tissues. This chapter provides an overview of biopotential monitoring, from the biological basis to the circuit and system techniques. Signal acquisition, processing, and transmission are fundamental capabilities of biomedical research and medical devices development. In these topics, integrated, low-power consumption systems for portable, wearable, or implantable monitoring of neural signals are taken as study case, presenting both current research trends and established solutions. Starting from the biological sources of the biopotentials, the main observation levels are presented. The design of the integrated front-end amplifier, which must cope with the tougher trade-offs, is discussed, and the system level requirements and alternatives for data acquisition, processing, and wireless transmission are summarized.
eu_rights_str_mv openAccess
format article
id anni_ebdefe5f043bce4eda67e4b3bdcabd88
identifier_str_mv Oreggioni, J, Caputi, Á y Silveira, F. Biopotential monitoring [en línea]. En: Encyclopedia of Biomedical Engineering. Amsterdam : Elsevier, 2019, pp. 296-304. ISBN: 978-0-12-805144-3.
978-0-12-805144-3
instacron_str Universidad de la República
institution Universidad de la República
instname_str Universidad de la República
language eng
language_invalid_str_mv en
network_acronym_str anni
network_name_str oai-lr-anni
oai_identifier_str oai:colibri.udelar.edu.uy:20.500.12008/23468
publishDate 2019
publishDateSort 2019
publisher.none.fl_str_mv Elsevier
reponame_str COLIBRI
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
spelling Biopotential monitoringOreggioni, JuliánCaputi, ÁngelSilveira, FernandoAnalog front-endBiomedical integrated circuitBiopotential amplifierBiopotential monitoring specificationsBiopotential organization levelsBiopotential sourcesLow-power wireless communicationNeural recordingWireless biopotential monitoringINGENIERIA BIOMEDICABiopotentials measurements are essential for biological research and biomedical monitoring of excitable tissues. This chapter provides an overview of biopotential monitoring, from the biological basis to the circuit and system techniques. Signal acquisition, processing, and transmission are fundamental capabilities of biomedical research and medical devices development. In these topics, integrated, low-power consumption systems for portable, wearable, or implantable monitoring of neural signals are taken as study case, presenting both current research trends and established solutions. Starting from the biological sources of the biopotentials, the main observation levels are presented. The design of the integrated front-end amplifier, which must cope with the tougher trade-offs, is discussed, and the system level requirements and alternatives for data acquisition, processing, and wireless transmission are summarized.ElsevierOreggioni Julián, Universidad de la República (Uruguay). Facultad de Ingeniería.Caputi Ángel, Uruguay. Ministerio de Educación y Cultura. Instituto de Investigaciones Biológicas Clemente Estable.Silveira Fernando, Universidad de la República (Uruguay). Facultad de Ingeniería.2020-04-02T20:31:45Z2020-04-02T20:31:45Z2019Artículoinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion15 p.application/pdfOreggioni, J, Caputi, Á y Silveira, F. Biopotential monitoring [en línea]. En: Encyclopedia of Biomedical Engineering. Amsterdam : Elsevier, 2019, pp. 296-304. ISBN: 978-0-12-805144-3.978-0-12-805144-3https://hdl.handle.net/20.500.12008/23468reponame:COLIBRIinstname:Universidad de la Repúblicainstacron:Universidad de la RepúblicaenengEncyclopedia of Biomedical EngineeringLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)info:eu-repo/semantics/openAccessLicencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)oai:colibri.udelar.edu.uy:20.500.12008/234682026-04-14T10:15:09Z
spellingShingle Biopotential monitoring
Oreggioni, Julián
Analog front-end
Biomedical integrated circuit
Biopotential amplifier
Biopotential monitoring specifications
Biopotential organization levels
Biopotential sources
Low-power wireless communication
Neural recording
Wireless biopotential monitoring
INGENIERIA BIOMEDICA
status_str publishedVersion
title Biopotential monitoring
title_full Biopotential monitoring
title_fullStr Biopotential monitoring
title_full_unstemmed Biopotential monitoring
title_short Biopotential monitoring
title_sort Biopotential monitoring
topic Analog front-end
Biomedical integrated circuit
Biopotential amplifier
Biopotential monitoring specifications
Biopotential organization levels
Biopotential sources
Low-power wireless communication
Neural recording
Wireless biopotential monitoring
INGENIERIA BIOMEDICA