Analysis of evaluating methods for transformer chopped impulse tests

Power transformers must be tested under high voltage impulse tests with full-length and chopped wave- forms. This paper compares different evaluation methods used for lighting impulse chopped tests, showing the advantages and drawbacks of them. The evaluation technique compares voltage and current w...

Fuld beskrivelse

Saved in:
Bibliografiske detaljer
Hovedforfatter: Joskowicz, José (author)
Andre forfattere: Slomovitz, Gabriel (author), Slomovitz, Daniel (author)
Format: article
Sprog:engelsk
Udgivet: 2015
Fag:
Online adgang:https://hdl.handle.net/20.500.12008/42658
Tags: Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!
_version_ 1868890220379766784
author Joskowicz, José
author2 Slomovitz, Gabriel
Slomovitz, Daniel
author2_role author
author
author_browse Joskowicz, José
Slomovitz, Daniel
Slomovitz, Gabriel
author_facet Joskowicz, José
Slomovitz, Gabriel
Slomovitz, Daniel
author_role author
collection COLIBRI
dc.creator.none.fl_str_mv Joskowicz, José
Slomovitz, Gabriel
Slomovitz, Daniel
dc.date.none.fl_str_mv 2015
2024-02-26T19:52:29Z
2024-02-26T19:52:29Z
20240223
dc.identifier.none.fl_str_mv Joskowicz, J, Slomovitz, G, Slomovitz, D. "Analysis of evaluating methods for transformer chopped impulse tests" Sop Transactions on Power Transmission and Smart Grid, 2015
https://hdl.handle.net/20.500.12008/42658
dc.language.none.fl_str_mv en
eng
dc.publisher.none.fl_str_mv PTSG
dc.relation.none.fl_str_mv Sop Transactions on Power Transmission and Smart Grid, 2015
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
dc.source.none.fl_str_mv reponame:COLIBRI
instname:Universidad de la República
instacron:Universidad de la República
dc.subject.none.fl_str_mv Impulse test
Transformer
Chopped waveform
Comparison
Standard
Transfer function
High voltage
Dielectric
Rod-rod gap
Multiple chopping gap
Telecomunicaciones
dc.title.none.fl_str_mv Analysis of evaluating methods for transformer chopped impulse tests
dc.type.none.fl_str_mv Artículo
info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
description Power transformers must be tested under high voltage impulse tests with full-length and chopped wave- forms. This paper compares different evaluation methods used for lighting impulse chopped tests, showing the advantages and drawbacks of them. The evaluation technique compares voltage and current wave- forms corresponding to reduced-level and full-level voltages. Any difference between the waveforms may correspond to a failure in the transformer under test. However, with chopped waveforms, impulse genera- tors may have significant differences in the time of chopping, so that low-level and full-level waveforms are different, making difficult to get a conclusion on the test result. Typical evaluating methods and a new recently proposed algorithm are compared using different power transformers and chopping times.
eu_rights_str_mv openAccess
format article
id anni_e6cf67c1f6ecd36ba8a8d3c8f3ec48e7
identifier_str_mv Joskowicz, J, Slomovitz, G, Slomovitz, D. "Analysis of evaluating methods for transformer chopped impulse tests" Sop Transactions on Power Transmission and Smart Grid, 2015
instacron_str Universidad de la República
institution Universidad de la República
instname_str Universidad de la República
language eng
language_invalid_str_mv en
network_acronym_str anni
network_name_str oai-lr-anni
oai_identifier_str oai:colibri.udelar.edu.uy:20.500.12008/42658
publishDate 2015
publishDateSort 2015
publisher.none.fl_str_mv PTSG
reponame_str COLIBRI
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
spelling Analysis of evaluating methods for transformer chopped impulse testsJoskowicz, JoséSlomovitz, GabrielSlomovitz, DanielImpulse testTransformerChopped waveformComparisonStandardTransfer functionHigh voltageDielectricRod-rod gapMultiple chopping gapTelecomunicacionesPower transformers must be tested under high voltage impulse tests with full-length and chopped wave- forms. This paper compares different evaluation methods used for lighting impulse chopped tests, showing the advantages and drawbacks of them. The evaluation technique compares voltage and current wave- forms corresponding to reduced-level and full-level voltages. Any difference between the waveforms may correspond to a failure in the transformer under test. However, with chopped waveforms, impulse genera- tors may have significant differences in the time of chopping, so that low-level and full-level waveforms are different, making difficult to get a conclusion on the test result. Typical evaluating methods and a new recently proposed algorithm are compared using different power transformers and chopping times.PTSG2024-02-26T19:52:29Z2024-02-26T19:52:29Z201520240223Artículoinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionJoskowicz, J, Slomovitz, G, Slomovitz, D. "Analysis of evaluating methods for transformer chopped impulse tests" Sop Transactions on Power Transmission and Smart Grid, 2015https://hdl.handle.net/20.500.12008/42658reponame:COLIBRIinstname:Universidad de la Repúblicainstacron:Universidad de la RepúblicaenengSop Transactions on Power Transmission and Smart Grid, 2015Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)info:eu-repo/semantics/openAccessLicencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)oai:colibri.udelar.edu.uy:20.500.12008/426582026-04-14T10:15:49Z
spellingShingle Analysis of evaluating methods for transformer chopped impulse tests
Joskowicz, José
Impulse test
Transformer
Chopped waveform
Comparison
Standard
Transfer function
High voltage
Dielectric
Rod-rod gap
Multiple chopping gap
Telecomunicaciones
status_str publishedVersion
title Analysis of evaluating methods for transformer chopped impulse tests
title_full Analysis of evaluating methods for transformer chopped impulse tests
title_fullStr Analysis of evaluating methods for transformer chopped impulse tests
title_full_unstemmed Analysis of evaluating methods for transformer chopped impulse tests
title_short Analysis of evaluating methods for transformer chopped impulse tests
title_sort Analysis of evaluating methods for transformer chopped impulse tests
topic Impulse test
Transformer
Chopped waveform
Comparison
Standard
Transfer function
High voltage
Dielectric
Rod-rod gap
Multiple chopping gap
Telecomunicaciones
url https://hdl.handle.net/20.500.12008/42658