Total knee replacement evaluation with Dynamic CINARTRO Method

Videofluoroscopy is used to evaluate the movement of the knee. The use of CINARTRO is here extended to Total Knee Replacement follow up, after incipient use in Anterior Cruciate Ligament repair. Tibial Femoral Contact Point (TFCP) migration is smaller (42%) in prosthetic knees with respect to normal...

תיאור מלא

שמור ב:
מידע ביבליוגרפי
מחבר ראשי: Artigas, José (author)
מחברים אחרים: Santos, Alejandro (author), Simini, Franco (author)
פורמט: article
שפה:אנגלית
יצא לאור: 2018
נושאים:
גישה מקוונת:https://hdl.handle.net/20.500.12008/43523
תגים: הוספת תג
אין תגיות, היה/י הראשונ/ה לתייג את הרשומה!
_version_ 1868890201510641664
author Artigas, José
author2 Santos, Alejandro
Simini, Franco
author2_role author
author
author_browse Artigas, José
Santos, Alejandro
Simini, Franco
author_facet Artigas, José
Santos, Alejandro
Simini, Franco
author_role author
collection COLIBRI
dc.creator.none.fl_str_mv Artigas, José
Santos, Alejandro
Simini, Franco
dc.date.none.fl_str_mv 2018
2024-04-16T16:21:11Z
2024-04-16T16:21:11Z
20240416
dc.identifier.none.fl_str_mv Artigas, J, Santos, A, Simini, F. "Total knee replacement evaluation with Dynamic CINARTRO Method" Revista Argentina de Bioingeniería, v 22, no, 1, 2018
https://hdl.handle.net/20.500.12008/43523
2591-376X
dc.language.none.fl_str_mv en
eng
dc.publisher.none.fl_str_mv Sociedad Argentina de Bioingeniería
dc.relation.none.fl_str_mv Revista Argentina de Bioingeniería, v 22, no, 1, 2018
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
dc.source.none.fl_str_mv reponame:COLIBRI
instname:Universidad de la República
instacron:Universidad de la República
dc.subject.none.fl_str_mv Functional dynamic imaging
X rays
Videofluoroscopy
Prosthesis
Total knee replacement
Sistemas y Control
dc.title.none.fl_str_mv Total knee replacement evaluation with Dynamic CINARTRO Method
dc.type.none.fl_str_mv Artículo
info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
description Videofluoroscopy is used to evaluate the movement of the knee. The use of CINARTRO is here extended to Total Knee Replacement follow up, after incipient use in Anterior Cruciate Ligament repair. Tibial Femoral Contact Point (TFCP) migration is smaller (42%) in prosthetic knees with respect to normal knees (55%). Considering flexion-extension stages separately, the TFCP migration at full extension has a greater value (64%) than at mid extension and flexion (50% & 54%). The same behaviour is also observed for prosthetic knees, but all values reduced: a high of 50% at extension follows 37% & 41%. This can be interpreted as a prosthetic restored near-physiological behaviour.
eu_rights_str_mv openAccess
format article
id anni_d38abd39e8d3a599c811cef5a6748eb2
identifier_str_mv Artigas, J, Santos, A, Simini, F. "Total knee replacement evaluation with Dynamic CINARTRO Method" Revista Argentina de Bioingeniería, v 22, no, 1, 2018
2591-376X
instacron_str Universidad de la República
institution Universidad de la República
instname_str Universidad de la República
language eng
language_invalid_str_mv en
network_acronym_str anni
network_name_str oai-lr-anni
oai_identifier_str oai:colibri.udelar.edu.uy:20.500.12008/43523
publishDate 2018
publishDateSort 2018
publisher.none.fl_str_mv Sociedad Argentina de Bioingeniería
reponame_str COLIBRI
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
spelling Total knee replacement evaluation with Dynamic CINARTRO MethodArtigas, JoséSantos, AlejandroSimini, FrancoFunctional dynamic imagingX raysVideofluoroscopyProsthesisTotal knee replacementSistemas y ControlVideofluoroscopy is used to evaluate the movement of the knee. The use of CINARTRO is here extended to Total Knee Replacement follow up, after incipient use in Anterior Cruciate Ligament repair. Tibial Femoral Contact Point (TFCP) migration is smaller (42%) in prosthetic knees with respect to normal knees (55%). Considering flexion-extension stages separately, the TFCP migration at full extension has a greater value (64%) than at mid extension and flexion (50% & 54%). The same behaviour is also observed for prosthetic knees, but all values reduced: a high of 50% at extension follows 37% & 41%. This can be interpreted as a prosthetic restored near-physiological behaviour.Sociedad Argentina de Bioingeniería2024-04-16T16:21:11Z2024-04-16T16:21:11Z201820240416Artículoinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtigas, J, Santos, A, Simini, F. "Total knee replacement evaluation with Dynamic CINARTRO Method" Revista Argentina de Bioingeniería, v 22, no, 1, 2018https://hdl.handle.net/20.500.12008/435232591-376Xreponame:COLIBRIinstname:Universidad de la Repúblicainstacron:Universidad de la RepúblicaenengRevista Argentina de Bioingeniería, v 22, no, 1, 2018Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)info:eu-repo/semantics/openAccessLicencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)oai:colibri.udelar.edu.uy:20.500.12008/435232026-04-14T10:15:55Z
spellingShingle Total knee replacement evaluation with Dynamic CINARTRO Method
Artigas, José
Functional dynamic imaging
X rays
Videofluoroscopy
Prosthesis
Total knee replacement
Sistemas y Control
status_str publishedVersion
title Total knee replacement evaluation with Dynamic CINARTRO Method
title_full Total knee replacement evaluation with Dynamic CINARTRO Method
title_fullStr Total knee replacement evaluation with Dynamic CINARTRO Method
title_full_unstemmed Total knee replacement evaluation with Dynamic CINARTRO Method
title_short Total knee replacement evaluation with Dynamic CINARTRO Method
title_sort Total knee replacement evaluation with Dynamic CINARTRO Method
topic Functional dynamic imaging
X rays
Videofluoroscopy
Prosthesis
Total knee replacement
Sistemas y Control
url https://hdl.handle.net/20.500.12008/43523