Modeling of heat leak effect in round trip efficiency for Brayton pumped heat energy storage with liquid media, by cooling and heating of the reservoirs tanks

For a pumped heat energy storage technology with commercial solar salt and a cold fluid such as methanol, the performance in long times of the Brayton like model associated to the losses of the four tanks (two high temperature units and two low temperature units) was studied. A round trip efficiency...